- It is necessary that the window be installed plumb, level
and square to insure proper performance and achieve compliance
with manufacturer's warranty.
- Close and lock sash before installing window.
- Using a premium grade exterior silicone caulk, caulk the
inside of the window fin where the fin will contact the
rough opening (See top corner detail in Illustration A below).
- Center and level window in opening. Nail one top corner
(1 3/4" roofing nails are recommended.) Then nail opposite
corner making sure the window top is level. This will hang
window to help assure unit is plumb, level and square.
- Shim window side jambs properly locating shims to minimize
deflection of the frame. Use shims under frame jamb at sill
to square window as required (See bottom window detail in
Illustration B below.)
- Complete installation by nailing every other hole from
the top down.
- Use fiberglass insulation (or equal) to fill all perimeter
voids. (Do not use expandable foam insulation because of
the possible chance for frame distortion which could impede
proper operation of unit.)
- To avoid water seepage, always flash around perimeter
after window is installed.
- Caulk the exterior perimeter between window frame and
trim.
These instructions are meant as a guide only. They will
cover most basic installation procedures, however, code
compliance and architectural design may differ from instructions.